Electrical design | PNP/NPN; (configurable) |
---|---|
Communication interface | IO-Link |
Dimensions [mm] | 250 x 28 x 16.7 |
Application | Continuous level measurement behind non-metallic and non-conductive surfaces |
---|---|
Media | dry bulk material; aqueous solutions; oils |
Cannot be used for | very adhesive media |
Operating voltage [V] | 10...30 DC; (IO-Link: 18...30 DC) |
---|---|
Current consumption [mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Max. power-on delay time [ms] | 1300 |
Measuring principle | capacitive |
Number of inputs and outputs | Number of digital outputs: 3 |
---|
Electrical design | PNP/NPN; (configurable) |
---|---|
Number of digital outputs | 3 |
Permanent current rating of switching output DC [mA] | 200 |
Max. resistance switching output [Ω] | 8 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring range [mm] | < 200 |
---|
Detection range [mm] | 228 |
---|---|
Set point SP [%] | 5...95 |
Reset point rP [%] | 4...94 |
In steps of [%] | 1 |
Repeatability [% of the final value] | 2 |
---|---|
Offset deviation [% of the final value] | 4 |
Resolution [% of the final value] | 1 |
Linearity deviation [% of the final value] | 1 |
Response time [ms] | 1300 |
---|
Parameter setting options | Damping; hysteresis / window; fault indication; Diagnostic function; Sensitivity; internal temperature; limitation of measuring range; adjustable switching delay; zero-point calibration; direction of installation; LEDs can be deactivated |
---|
Communication interface | IO-Link | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||||||||
IO-Link revision | 1.1 | ||||||||||
SDCI standard | IEC 61131-9 | ||||||||||
Profiles | Digital Measuring Sensor Profile, Common Profile | ||||||||||
SIO mode | yes | ||||||||||
Required master port class | A | ||||||||||
Process data analog | 1 | ||||||||||
Process data binary | 3 | ||||||||||
Min. process cycle time [ms] | 9.6 | ||||||||||
IO-Link process data (cyclical) |
|
||||||||||
IO-Link functions (acyclical) | direction of installation; limitation of sensor elements; Sensitivity; minimum recognition threshold; Performance in case of a fault; error delay; Damping; LED mode; switch-on cycle counter; operating hours counter; switching cycles counter; min./max. process value; internal temperature; min./max. internal temperature; diagnostic data level | ||||||||||
Supported DeviceIDs |
|
||||||||||
Note |
|
Applications | DIN EN 60654-1 application class B2 |
---|---|
Ambient temperature [°C] | -20...80 |
Storage temperature [°C] | -25...85 |
Protection | IP 65 |
EMC |
|
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Shock resistance |
|
||||||||||||||
Vibration resistance |
|
||||||||||||||
MTTF [years] | 290.43 | ||||||||||||||
UL approval |
|