Product characteristics
Number of inputs and outputs Number of digital outputs: 2
Measuring range
1...20 l/min 0.06...1.2 m³/h
Process connection threaded connection G 1/2 DN8
Application
System gold-plated contacts
Application for industrial applications
Media water; glycol solutions; Coolants
Medium temperature [°C] -10...90
Pressure rating [bar] 12
Pressure rating [MPa] 1.2
Note on pressure rating
up to 40 °C
MAWP (for applications according to CRN) [bar] 3.9
Electrical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 30
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2
Outputs
Total number of outputs 2
Output signal switching signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Short-circuit protection yes
Overload protection yes
Measuring/setting range
Measuring range
1...20 l/min 0.06...1.2 m³/h
Display range
0...24 l/min 0...1.44 m³/h
Resolution
0.1 l/min 0.005 m³/h
Set point SP
1.2...20 l/min 0.07...1.2 m³/h
Reset point rP
1...19.8 l/min 0.06...1.19 m³/h
Frequency end point, FEP
4...20 l/min 0.24...1.2 m³/h
In steps of
0.1 l/min 0.005 m³/h
Frequency at the end point FRP [Hz] 100...1000
Measuring dynamics 1:20
Temperature monitoring
Measuring range [°C] -10...90
Display range [°C] -30...110
Resolution [°C] 0.5
Set point SP [°C] -9...90
Reset point rP [°C] -10...89
In steps of [°C] 0.5
Frequency start point, FSP [°C] -10...70
Frequency end point, FEP [°C] 10...90
Frequency at the end point FRP [Hz] 100...1000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) ± 2 % MEW; (water)
Repeatability ± 0,5 % MEW
Temperature monitoring
Accuracy [K] ± 1
Reaction times
Flow monitoring
Response time [s] 1; (dAP = 0)
Damping process value dAP [s] 0...5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 6
Software / programming
Parameter setting options hysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port class A
Process data analog 2
WE’RE HERE TO HELP

Call us! 1-866-939-7717.
Mon-Fri 8am - 4pm EST

CHAT WITH US

We offer chat support.

Mon-Fri 8am - 4pm EST

USA & CAD LOCATIONS

To better serve you!

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare