Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
-50...1000 mbar -0.72...14.5 psi -20...401.5 inH2O -5...100 kPa
Process connection threaded connection G 1 external thread Aseptoflex Vario
Application
System gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25...150
Min. bursting pressure
30000 mbar 435 psi 3000 kPa
Pressure rating
10000 mbar 145 psi 1000 kPa
Vacuum resistance [mbar] -1000
Type of pressure relative pressure; vacuum
No dead space yes
MAWP (for applications according to CRN) [bar] 10
Electrical data
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage [V] 20...30 DC
Current consumption [mA] 3.5...21.5
Power-on delay time [s] < 1
3-wire
Operating voltage [V] 18...30 DC
Current consumption [mA] 5...45; (430 bei max. Laststrom)
Power-on delay time [s] < 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Number of analog outputs 1
Analog current output [mA] 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
2-wire
Max. load [Ω] 300
3-wire
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 125
Max. load [Ω] (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V)
Measuring/setting range
Measuring range
-50...1000 mbar -0.72...14.5 psi -20...401.5 inH2O -5...100 kPa
Set point SP
-49...1000 mbar -0.7...14.5 psi -19.5...401.5 inH2O -4.9...100 kPa
Reset point rP
-50...999 mbar -0.73...14.48 psi -20.1...400.9 inH2O -5...99.9 kPa
Analog start point
-50...800 mbar -0.73...11.6 psi -20.1...321.2 inH2O -5...80 kPa
Analog end point
150...1000 mbar 2.18...14.5 psi 60.2...401.5 inH2O 15...100 kPa
Min. difference between SP and rP
2 mbar 0.03 psi 0.6 inH2O 0.2 kPa
In steps of
1 mbar 0.01 psi 0.1 inH2O 0.1 kPa
Factory setting
SP1 =250 mbar rP1 = 230 mbar
SP2 = 750 mbar rP2 = 730 mbar
ASP = 0.00 mbar AEP = 1000 mbar
dAP = 2.00 s dAA =2.00 s
Temperature monitoring
Measuring range
-25...150 °C -13...302 °F
Accuracy / deviations
Switch point accuracy [% of the span] < ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability [% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
WE’RE HERE TO HELP

Call us! 1-866-939-7717.
Mon-Fri 8am - 4pm EST

CHAT WITH US

We offer chat support.

Mon-Fri 8am - 4pm EST

USA & CAD LOCATIONS

To better serve you!

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare