Electrical Specifications:
-
AC Voltage Measurement:
-
Range:
- 600.0 mV
- 6.000 V
- 60.00 V
- 600.0 V
- 1000 V¹
-
Resolution:
- 0.1 mV
- 0.001 V
- 0.01 V
- 0.1 V
- 1 V
-
Accuracy 50 Hz to 60 Hz:
- ±(% of Rdg + Counts): ±(1% + 3)
-
Accuracy 60 Hz to 5000 Hz:
- ±(% of Rdg + Counts): ±(2% + 3)
- ¹ 1 kHz bandwidth
-
Range:
-
Low-Pass Filter Voltage:
-
Range:
- 600.0 mV
- 6.000 V
- 60.00 V
- 600.0 V
- 1000 V¹
-
Resolution:
- 0.1 mV
- 0.001 V
- 0.01 V
- 0.1 V
- 1 V
-
Accuracy 50 Hz to 60 Hz:
- ±(% of Rdg + Counts): ±(1% + 3)
-
Accuracy 60 Hz to 400 Hz:
- ±(% of Rdg + Counts): +(2% + 3), -(6% - 3)
- ¹ 1 kHz bandwidth
-
Range:
-
DC Voltage Measurement:
-
Range Resolution: Accuracy ±(% of Rdg + Counts):
- 6.000 V dc 0.001 V ±(0.09% + 2)
- 60.00 V dc 0.01 V ±(0.09% + 2)
- 600.0 V dc 0.1 V ±(0.09% + 2)
- 1000 V dc 1 V ±(0.09% + 2)
- Input Impedance: 10 MΩ (nominal), <100 pF
- Normal Mode Rejection Ratio: >60 dB @ 50 Hz or 60 Hz
- Common Mode Rejection Ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
- **Accuracies Apply to ± 100% of Range
-
Range Resolution: Accuracy ±(% of Rdg + Counts):
-
DC Millivolts Measurement:
-
Range Resolution: Accuracy ±(% of Rdg + Counts):
- 600.0 mVdc 0.1 mV ±(0.1% + 1)
-
Range Resolution: Accuracy ±(% of Rdg + Counts):
-
DC and AC Current Measurement:
-
AC 45 Hz to 1000 Hz:
-
Range Resolution: Accuracy ±(% of Rdg+Counts):
- 400 mA 0.1 mA ±(1.5% + 2)¹
- Burden Voltage (Typical): 2 mV/mA
-
Range Resolution: Accuracy ±(% of Rdg+Counts):
- 60 mA 0.01 mA ±(1.5% + 2)¹
- Burden Voltage (Typical): 2 mV/mA
-
Range Resolution: Accuracy ±(% of Rdg+Counts):
-
DC:
-
Range Resolution: Accuracy ±(% of Rdg+Counts):
- 400 mA 0.1 mA ±(0.2% + 2)
- Burden Voltage (Typical): 2 mV/mA
-
Range Resolution: Accuracy ±(% of Rdg+Counts):
- 60 mA 0.01 mA ±(0.2% + 2)
- Burden Voltage (Typical): 2 mV/mA
-
Range Resolution: Accuracy ±(% of Rdg+Counts):
- Overload: 600 mA for 2 minutes maximum
- Fuse Protection for mA Input: 0.44 mA, 1000 V, IR 10 kA
-
AC 45 Hz to 1000 Hz: