Electrical Specifications:

  • AC Voltage Measurement:

    • Range:
      • 600.0 mV
      • 6.000 V
      • 60.00 V
      • 600.0 V
      • 1000 V¹
    • Resolution:
      • 0.1 mV
      • 0.001 V
      • 0.01 V
      • 0.1 V
      • 1 V
    • Accuracy 50 Hz to 60 Hz:
      • ±(% of Rdg + Counts): ±(1% + 3)
    • Accuracy 60 Hz to 5000 Hz:
      • ±(% of Rdg + Counts): ±(2% + 3)
      • ¹ 1 kHz bandwidth
  • Low-Pass Filter Voltage:

    • Range:
      • 600.0 mV
      • 6.000 V
      • 60.00 V
      • 600.0 V
      • 1000 V¹
    • Resolution:
      • 0.1 mV
      • 0.001 V
      • 0.01 V
      • 0.1 V
      • 1 V
    • Accuracy 50 Hz to 60 Hz:
      • ±(% of Rdg + Counts): ±(1% + 3)
    • Accuracy 60 Hz to 400 Hz:
      • ±(% of Rdg + Counts): +(2% + 3), -(6% - 3)
      • ¹ 1 kHz bandwidth
  • DC Voltage Measurement:

    • Range Resolution: Accuracy ±(% of Rdg + Counts):
      • 6.000 V dc 0.001 V ±(0.09% + 2)
      • 60.00 V dc 0.01 V ±(0.09% + 2)
      • 600.0 V dc 0.1 V ±(0.09% + 2)
      • 1000 V dc 1 V ±(0.09% + 2)
    • Input Impedance: 10 MΩ (nominal), <100 pF
    • Normal Mode Rejection Ratio: >60 dB @ 50 Hz or 60 Hz
    • Common Mode Rejection Ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
    • **Accuracies Apply to ± 100% of Range
  • DC Millivolts Measurement:

    • Range Resolution: Accuracy ±(% of Rdg + Counts):
      • 600.0 mVdc 0.1 mV ±(0.1% + 1)
  • DC and AC Current Measurement:

    • AC 45 Hz to 1000 Hz:
      • Range Resolution: Accuracy ±(% of Rdg+Counts):
        • 400 mA 0.1 mA ±(1.5% + 2)¹
      • Burden Voltage (Typical): 2 mV/mA
      • Range Resolution: Accuracy ±(% of Rdg+Counts):
        • 60 mA 0.01 mA ±(1.5% + 2)¹
      • Burden Voltage (Typical): 2 mV/mA
    • DC:
      • Range Resolution: Accuracy ±(% of Rdg+Counts):
        • 400 mA 0.1 mA ±(0.2% + 2)
      • Burden Voltage (Typical): 2 mV/mA
      • Range Resolution: Accuracy ±(% of Rdg+Counts):
        • 60 mA 0.01 mA ±(0.2% + 2)
      • Burden Voltage (Typical): 2 mV/mA
    • Overload: 600 mA for 2 minutes maximum
    • Fuse Protection for mA Input: 0.44 mA, 1000 V, IR 10 kA