Ifm SD8601 Industrial Gas Counter
Ifm SD8601 Industrial Gas Counter is backordered and will ship as soon as it is back in stock.
Industrial Automation Parts is only an authorized distributor for DeLock and is not authorized for any other manufacturers. Manufacturer's warranty and support do not apply. Our IAP warranty of three months is applicable.
Delivery And Shipping
Delivery And Shipping
Both Standard and Express shipping options are available at checkout.
Subscribe to our newsletter
Sign up for exclusive offers.
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|---|
Measuring range [scfh] | 25...7945 |
Measuring range [scfm] | 0.4...132.4 |
Measuring range [ft/s] | 1.2...340.2 |
Process connection | threaded connection 1" NPT DN25 |
Application | for industrial applications |
---|---|
Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air |
Medium temperature [°F] | 14...140 |
Min. bursting pressure [psi] | 928 |
Pressure rating [psi] | 232 |
MAWP (for applications according to CRN) [bar] | 10.5 |
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 80 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|
Inputs | counter reset |
---|
Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
---|---|
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 150; (per output) |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring range [scfh] | 25...7945 |
---|---|
Measuring range [scfm] | 0.4...132.4 |
Measuring range [ft/s] | 1.2...340.2 |
Display range [scfh] | 0...9535 |
Display range [scfm] | 0...158.9 |
Display range [ft/s] | 0...408.2 |
Resolution [scfh] | 5 |
Resolution [scfm] | 0.1 |
Resolution [ft/s] | 0.2 |
Set point SP [scfh] | 69...7943 |
Set point SP [scfm] | 1.1...132.4 |
Set point SP [ft/s] | 3...340.1 |
Reset point rP [scfh] | 30...7904 |
Reset point rP [scfm] | 0.5...131.7 |
Reset point rP [ft/s] | 1.3...338.4 |
Analog start point ASP [scfh] | 0...6357 |
Analog start point ASP [scfm] | 0...105.9 |
Analog start point ASP [ft/s] | 0...272.2 |
Analog end point AEP [scfh] | 1589...7946 |
Analog end point AEP [scfm] | 26.5...132.4 |
Analog end point AEP [ft/s] | 68...340.2 |
Low flow cut-off LFC [scfh] | 9...85 |
Low flow cut-off LFC [scfm] | 0.2...1.4 |
Low flow cut-off LFC [ft/s] | 0.4...3.6 |
In steps of [scfh] | 1 |
In steps of [scfm] | 0.1 |
In steps of [ft/s] | 0.1 |
Measuring range [psi] | -15...232 |
---|---|
Display range [psi] | -15...290 |
Resolution [psi] | 1 |
Set point SP [psi] | -13...232 |
Reset point rP [psi] | -15...231 |
Analog start point [psi] | -15...186 |
Analog end point [psi] | 32...232 |
In steps of [psi] | 1 |
Measuring range |
|
||
---|---|---|---|
Display range |
|
||
Set point SP |
|
||
Pulse value |
|