Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 | |||
---|---|---|---|---|
Measuring range |
|
|||
Process connection | threaded connection R 1/2 external thread DN15 |
Application | for industrial applications | |||
---|---|---|---|---|
Media | compressed air | |||
Note on media |
|
|||
Medium temperature [°C] | 0...60 | |||
Pressure rating [bar] | 16 | |||
Pressure rating [MPa] | 1.6 | |||
MAWP (for applications according to CRN) [bar] | 16 |
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 110 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring range |
|
|||
---|---|---|---|---|
Display range |
|
|||
Set point SP |
|
|||
Reset point rP |
|
|||
Analog start point ASP |
|
|||
Analog end point AEP |
|
|||
In steps of |
|
Pulse value | 0.001...1000000 m³ |
---|---|
In steps of | 0.001 m³ |
Pulse length [s] | 0,02...2 |
Measuring range [°C] | 0...60 |
---|---|
Display range [°C] | -12...72 |
Repeatability [% of the measured value] | ± 1,5 |
---|---|
Accuracy (in the measuring range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
---|
Response time [s] | 0.1; (dAP = 0) |
---|---|
Damping process value dAP in steps [s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
---|
Communication interface | IO-Link |
---|---|
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
Profiles | no profile |
SIO mode | yes |
Required master port class | A |
Process data analog | 3 |