Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|---|
Process connection | threaded connection G 1/4 DN8 |
Measuring range [m³/h] | 0.08...24.04 |
---|
Measuring range [m³/h] | 0.04...14.36 |
---|
Measuring range [m³/h] | 0.04...15 |
---|
Application | for industrial applications |
---|---|
Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
Medium temperature [°C] | 0...60 |
Pressure rating [bar] | 16 |
Pressure rating [MPa] | 1.6 |
Operating voltage [V] | 18...30 DC; (to SELV/PELV) |
---|---|
Current consumption [mA] | < 100 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
---|
Total number of outputs | 2 |
---|---|
Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Low flow cut-off LFC [m³/h] | < 0.26 |
---|---|
Measuring dynamics | 1:300 |
Measuring range [m³/h] | 0.08...24.04 |
---|---|
Display range [m³/h] | 0...28.84 |
Resolution [m³/h] | 0.02 |
Set point SP [m³/h] | 0.22...24.04 |
Reset point rP [m³/h] | 0.12...23.94 |
Analog start point ASP [m³/h] | 0...19.24 |
Analog end point AEP [m³/h] | 4.8...24.04 |
In steps of [m³/h] | 0.02 |
Measuring range [m³/h] | 0.04...14.36 |
---|---|
Display range [m³/h] | 0...17.24 |
Resolution [m³/h] | 0.02 |
Set point SP [m³/h] | 0.14...14.36 |
Reset point rP [m³/h] | 0.08...14.3 |
Analog start point ASP [m³/h] | 0...11.48 |
Analog end point AEP [m³/h] | 2.88...14.36 |
In steps of [m³/h] | 0.02 |
Pulse value | 0.001...1 000 000 m³ |
---|---|
In steps of | 0.001...1000 m³ |
Pulse length [s] | 0,062...2 |
Measuring range [m³/h] | 0.04...15 |
---|---|
Display range [m³/h] | 0...18 |
Resolution [m³/h] | 0.02 |
Set point SP [m³/h] | 0.14...15 |
Reset point rP [m³/h] | 0.08...14.94 |
Analog start point ASP [m³/h] | 0...12 |
Analog end point AEP [m³/h] | 3...15 |
In steps of [m³/h] | 0.02 |
Measuring range [°C] | 0...60 |
---|---|
Display range [°C] | -12...72 |
Resolution [°C] | 0.2 |
Set point SP [°C] | 0.4...60 |
Reset point rP [°C] | 0...59.8 |
Analog start point [°C] | 0...48 |
Analog end point [°C] | 12...60 |
In steps of [°C] | 0.2 |
Repeatability [% of the measured value] | ± 1,5 |
---|---|
Accuracy (in the measuring range) |